present a dangerous situation. With ….
News
November 14, 2021
present a dangerous situation. With ….

present a dangerous situation. With either the circuit breaker GFCI or the receptacle GFCI, pushing the test button should turn off the power to the circuit. With receptacle GFCIs, pressing the test button should cause the reset button to pop up. With circuit breaker GFCIs, pressing the test button should cause the handle to move to the tripped position. In either case, remember to press the reset button or reset the handle to re-establish power and protection.

Many locations require GFCI protection, so it’s important to know how to install these devices. Installers need to understand how GFCIs function in order to provide their customers with the best installation.

But before attempting any electrical work, turn off the power at the service panel, and lock the electrical power box to prevent an unauthorized person from turning the power on.

GFCI receptacles have input holes or screws and output holes or screws referred to as the “line” leads and “load” leads. The line terminals are for connections from the service panel. The load terminals are to deliver power to another receptacle in the circuit. If there are no other receptacles on the circuit, the load lead should not be used. See Figure 2 on page 19.

The electrical cable coming from the service panel consists of two or three wires. It has a black hot wire, a white neutral wire, and a green grounding wire. From the service panel, the black hot wire is connected to a black or brass hot line terminal. The white wire is connected to the white or silver line terminal. The green wire is connected to the green grounding terminal.

One aspect of GFCI protection to consider is placement.

That is because the GFCI’s location along the circuit determines whether or not it also protects other receptacles along the circuit. See Figure 3 on GFCI placement.

If the GFCI is placed in position A, it will also provide protection to the load side, or receptacles B, C and D. If instead, the GFCI is in position D, it will not provide protection to receptacles A, B, and C.

When replacing an old receptacle, the situation can get complicated. For example, the existing receptacle may also be connected to another receptacle, and it’s important to identify its position in the series.

Remove the old receptacle from the electrical box. If there is only one cable consisting of 2 to 3 wires, the receptacle is probably in position D or else it is the sole receptacle for the circuit. See the graphic for GFCI placement.

On the other hand, when the old receptacle has been removed and there are two cables for a total of 4 to 6 wires, the receptacle is in position A, B, or C. Don’t assume that the old receptacle was correctly wired.

One common installation mistake that workers and even electricians make is what is called line load reversal. Current standards for GFCI devices make it so that if the line and load cables are acci- dently reversed, the device simply will not work. In older devices, however, it was possible to reverse the line and load connections.

In the case of some of the older GFCIs where the line and load cables are reversed, the outlet will continue to provide electricity, even when the test button has been pressed. Generally, people test their GFCIs by pressing the test button. This makes the reset button pop out, a signal that the outlet is now dead, and the GFCI has done its job. But with GFCIs where the line and load are reversed, that indicative pop still occurs, but the outlet is still live-a false positive. Furthermore, all outlets that are connected downstream of this outlet, presumed to be GFCI protected from the upstream GFCI, are also still live. It is common to find this mistake, and there are GFCI three-light testers that are available at most hardware stores that can diagnose this and other potentially dangerous situations.

Another installation mistake is called reversed polarity, where the hot wire is connected to the neutral terminal, while the neutral wire is connected to the hot terminal. See Figure 4. Appliances plugged into outlets whose polarity was reversed will still work, but they are dangerous. That’s because most appliances are wired to have the hot side of the circuit, not the neutral, controlled by their on/off switches.They present a shock hazard because even when they are off, if they are still plugged into an outlet and the hot and neutral wires were reversed, they are still getting electricity. People touching the outside metal of light bulbs and other appliances have been known to get shocked.


Figure 3: GFCI Placement. Pictured above, the GFCI is in the best position.

LATEST NEWS
Sodium bromide warning label change
News
Sodium bromide warning label change
EPA mandates NaBr product packaging state ‘Not for use in outdoor pools’
April 30, 2025
By Marcelle Dibrell The consequences of a 2021 EPA decision are now being felt by pool professionals who have long relied on sodium bromide for pool a...
this is a test
News
Service pros prepare safe summer pools
April 30, 2025
A pool and spa service technician’s job goes far beyond maintaining water clarity and balancing chemicals. Ensuring the safety of swimmers is a critic...
this is a test
News
Man drives car into swimming pool
April 30, 2025
A man died after driving his car into a backyard swimming pool. The fatal incident occurred in Brea, California, on April 18, when the man drove his c...
this is a test
News
Chlorine gas release at ‘The Club ’
April 30, 2025
Thirteen children were treated for chemical inhalation following a chlorine gas release at a California swimming pool club. The children were experien...
this is a test
News
Diving for eggs, toys and prizes
April 30, 2025
This year, public pools across the country made a splashy twist on a spring tradition by inviting families to dive in for underwater Easter egg hunts....
this is a test
News
Calling all Service Pros— Let’s check those gates
April 30, 2025
Safe Gates Help Save Lives – Check Your Pool Gate Month By D& D Technologies Drowning is the leading cause of accidental death in children ages 1-4 ye...
this is a test
Read Our Newsletter
ePaper
coogle_play
app_store
Free Subscription
View Current Print Ads
Educational Announcements
Aquatic Training Institute

Educational Leverage

Foundation For Pool Industry Education

Locey Pool

Pool Chemistry Training Institute

Pool & Hot Tub Alliance

Portofino University

Underwater Pool Masters
Trade Show Dates
  • The International Pool Spa Patio Expo
    Nov. 12-14, Dallas, Texas
  • The Pool and Spa Show
    Jan. 28-30, Atlantic City, New Jersey
  • 35th Annual National Plasterers Conference
    Feb. 26-28, Lake Buena Vista, Florida
  • The Southwest Pool and Spa Show
    Feb. 4-8, Houston, Texas
  • The Western Pool and Spa Show
    Feb. 6-8, Long Beach, California
Books to Order
About Us Terms of Use Privacy Policy
We use cookies to ensure that our website gives you the best experience possible. By continuing to use this website, you agree to this use of cookies.OK