August 14, 2024
Variable-speed pumps for top efficiency

Variable-speed pool pumps are designed to be highly energy-efficient and versatile compared to singlespeed and dual-speed pumps. They allow users to adjust the pump's speed to match the specific needs of their pool, providing optimal performance and significant energy savings.

Single-speed pumps operate at one constant speed, typically the highest speed the motor can handle, which often leads to excessive energy use and higher electricity bills. Dualspeed pumps have two settings: high speed for tasks such as vacuuming and low speed for regular filtration. While more efficient than singlespeed pumps, dual-speed pumps still lack the fine control that variablespeed pumps offer.

Variable-speed pumps, on the other hand, utilize permanent magnet motors (similar to those found in electric cars) and allow for precise speed adjustments. This means they can run at lower speeds for basic filtration, which uses significantly less energy, and at higher speeds for tasks that require more power, such as cleaning or running water features. The energy savings can be substantial, often reducing electricity consumption by up to 80 percent compared to single-speed pumps. This efficiency not only lowers utility bills but also extends the lifespan of the pump and other pool equipment by reducing wear and tear.

Properly sizing a variable-speed pump is crucial for maximizing efficiency and performance. The size of the pump should match the pool's specific requirements, primarily based on the pool’s volume and the desired turnover rate. The turnover rate is the time it takes for the pump to circulate an amount equal to the entire volume of pool water through the filtration system. For most pools, a turnover rate of 8 hours is recommended.

To calculate the required flow rate, you need to know the pool's volume. For example, if you have a 20,000-gallon pool and you want a turnover rate of 8 hours, you divide the total volume by the turnover rate: 20,000 gallons ÷ 8 hours = 2,500 gallons per hour (GPH). Converting this to gallons per minute (GPM), you get approximately 42 GPM (since there are 60 minutes in an hour).

Flow rate refers to the volume of water that passes through the pump in a given period, typically measured in GPM. Proper flow rates ensure that the pool is adequately filtered and that the water remains clear and safe for swimming. Too high a flow rate can cause excessive pressure on the filtration system, while too low a flow rate may not provide sufficient filtration.

Calculating the turnover rate and flow rate helps in selecting a pump that can handle the required workload efficiently.

Variable-speed pumps can be adjusted to maintain the ideal flow rate, ensuring efficient operation and optimal water quality. Because these pumps can run at lower speeds for extended periods, they can provide continuous filtration, which is often more effective than running at high speeds for shorter periods.

LATEST NEWS
Job opportunities remain despite AI surge
Use of artificial intelligence affecting many entry level jobs, but service remains strong
January 14, 2026
By Marcelle Dibrell The U.S. job market is at a turning point. Recent dat a shows higher unemployment overall and slowing job growth, but sectors like...
January 14, 2026
A suspected drunk driver was saved by a residential swimming pool that happened to be in the perfect location to break her fall when she was ejected f...
January 14, 2026
Blue Wave Brand is recalling all aboveground swimming pools, 48 inches and taller, due to a drowning hazard, effective December 18, 2025. The recalled...
January 14, 2026
For many service professionals, choosing a business structure happens quickly — often at the kitchen table, sometimes at the suggestion of an accounta...